# NOTES FOR SAFE OPERATION 

1、 How It Works
2、 4SSC5.2/101-D120/1300 Pump Description
2.1 Material of Parts
2.2 Pump Specification
2.3 Pump Performance Curve
3、 JL-197K1500 Controller General Information
3.1 Features
3.2 Technical Parameters
3.3 Label D
3.4 Program Setting
3.5 Light Indications
3.6 Wiring Instructions
3.6.1 Total Diagram of Terminals
3.6.2 Operation of Well(borehole) Level Sensor
3.6.3 Operation of Tank Level Sensor Level Sensor
4、 Solar Panel Configure and Connection way
Configured by 36Vmp(44Voc) Solar Panel
5、Mechanical and Electrical Installation
5.1 Outline & Installation Dimensions Diagram
5.2 Mechanical Installation
5.2.1 Overheat Protection
5.2.2 Location Selection
NOTES FOR SAFE OPERATION
■ BEFORE INSTALLATION         WARNING
 Do not install or operate damaged controller/pump or with missing parts.
 Ensure only qualified personnel to operate the system. Otherwise it may cause product damage or
personal injury.
 Use correct PV panel configuration and cable size following the technical guide strictly. Otherwise, it
may influence pump performance even result in damage to pump and controller.
 Maximum submersible depth of pump should ≤ 40 Mtrs. Otherwise, pump body may deform and the
flow and head performance may reduce due to the high water pressure.
■ INSTALLATION          CAUTION
 Install the controller in nonflammable material like metal. Otherwise it may cause a fire.
 The protective cabinet must prevent from moisture, insect or dust accumulation, which may cause
abnormal working condition of controller.
 The protective cabinet needs to set vents to ensure ambient temperature is below 45. High
temperature will damage the controller components.
 Use antistatic wrist strap while doing wiring. DO NOT touch the control board with hand directly.
Static electricity on human body will cause breakdown on some components instantaneously.
 Ensure PV array’s positive (PV+) and negative (PV-) are connected to controller’s PV+ and PV-
terminals correspondingly.
 Ensure pump’s U V W wires are connected to controller’s U V W terminals correspondingly.
Otherwise, the motor will run in reverse, and cannot give normal flow and head.
 DO NOT make pump’s U V W wires short circuit. It may cause the fuse blow out.
 CONNECT EACH TERMINAL TIGHT. Otherwise, the large contact resistance and the operating current
will cause the terminal to heat up severely.
 Make sure every joint of extension cable is tight and well waterproof.
WARNING
 Using dc breaker and surge protection device for safe purpose. Surge may cause big instantaneous
current and make the fuse blow out.
 DO NOT touch any terminals at energized condition.
■ OPERATION          CAUTION
 Do not open or remove the front cover of controller during running.
 In order to test the pump, the maximum DRY-RUN time should ≤ 15 seconds.
 If the pump turning is reversed, change any two lines of pump’s UVW wires.
■ MAINTENANCE AND INSPECTION         WARNING
 Only qualified or authorized professional personnel can maintain, replace and inspect the system.
Otherwise it may cause damage or personal injury.
 Wait at least 10 minutes after the power failure, or ensure there is no residual voltage before carry out
maintenance and inspection. Otherwise it may cause damage or personal injury.
■ AFTER-SALES
 If failing to follow above necessary instructions, resulting in damage to the system or personnel, it’s
not available to enjoy free warranty service from supplier.
1How It Works
Solar pumping system serves to provide water in remote applications where electrical grid
power is either unreliable or unavailable. BLDC solar pump controller can direct use the DC
power from PV array, and drive the Brushless DC pumps. In sunny days, the pumping system
can continuously pump water. There is no need of batteries or other energy storage devices.
It’s recommended to pump water to a reservoir for storage.
A float switch can be installed in the water tower to control the pump operation. And install a
low-level probe in well to detect the well water so that pump will stop when there is no water.
Figure 1 shows a typical diagram of the solar pumping system, including major parts and
components.
24SSC5.2/101-D120/1300 PUMP DESCRIPTION
2.1 DESCRIPTION OF MATERIAL
Motor:Full Oil Permanent Magnet Brushless DC Motor (Without Hall)
Outlet / Inlet:304 Stainless Steel
Pump Body:304 Stainless Steel
Motor Body:304 Stainless Steel
Impeller:304 Stainless Steel
Screw:304 Stainless Steel
Cable:3 Cores / 2 Meters / 2.0mm2
2.2 PUMP SPECIFICATION
Rated Voltage:120 VDC
Rated Power:1100 W
Max. Flow:5.2 m3/h
Max. Lift:101Mtrs.
Outlet Size:1.25 inch
Outline Size:4 inch

2.3 PUMP PERFORMANCE CURVE

3JL-197K1500 Controller General Information
3.1 FEATURES
The JL-197K1500 solar pump controller is designed with the high standard of reliability expected of
products. The controller attempts to drive the pump and motor to deliver water even under adverse
conditions, reducing output as necessary to protect the system components from damage, and only
shutting down in extreme cases. Full operation is restored automatically whenever abnormal conditions
subside.
Inspection
Before you begin, inspect the JL-197K1500 solar pump controller unit. Verify that the part number is
correct and no damage has occurred during transit.
NOTE: JL-197K1500 solar pump controller is the component of solar pumping system which has other
two components, PV array and Brushless DC pump.
Protection Features
Electronic monitoring gives the controller the capability to monitor the system and automatically shut
down in the event of:
• Dry well conditions – with low level switch
• Bound pump – with auto-reversing torque
• High Voltage Surge
• Low Input Voltage
• Open motor circuit
• Short circuit
• Over heat
NOTE: This controller provides motor overload protection by preventing motor current from exceeding
rating current and by limiting the duty cycle in the event of low water level. This controller does not
provide over temperature sensing of the motor.
System Diagnostics
The JL-197K1500 solar pump controller continuously monitors system performance and detects a variety
of abnormal conditions. In many cases, the controller will compensate as needed to maintain continuous
system operation; however, if there is high risk of equipment damage, the controller will protect the
system from the fault condition. If possible, the controller will try to restart itself when the fault condition
subsides.
Motor Soft-Start
Normally, when there is a demand for water and power is available, the JL-197K1500
solar pump controller will be operating. Whenever the JL-197K1500 solar pump controller detects a need
for water, the controller always
ramps upthe motor speed while gradually increasing motor voltage,
resulting in a cooler motor and lower start-up current compared to conventional water systems. This will
not harm the motor due to the controller’s soft-start feature.
Over Temperature Fold back
The JL-197K1500 solar pump controller is designed for full power operation from a solar array in ambient
temperatures up to 45. In excess of 45 temperature conditions, the controller will reduce output power
in an attempt to avoid shutdown. Full pump output is restored when the controller temperature cools to a
safe level.
Level Control Switch
The JL-197K1500 solar pump controller can access two water level switches(well level sensor and tank
level sensor) to detect remotely and control the pump automatically. Level switch for JL-197K1500 solar
pump controller is optional, not mandatory.
5.2.1 Overheat Protection
If in the outdoor, the controller shall be installed in a well ventilated place, and avoid direct sunlight and
rain. Extremely high temperature may cause the controller stop to protect itself. Using dc breaker and
surge protection device for safe purpose. Surge may cause big instantaneous current and make
the fuse blow out.
5.2.2 Location Selection
The JL-197K Series solar pump controller is intended for operation in maximum ambient temperatures up
to 45. In order to avoid overheating caused by the failure, it is recommended to install the controller in a
shadow position.
The JL-197K Series solar pump controller must be installed into a control box which has a tight enclosure
to avoid direct sunshine, rain, dust, moisture, animals, plants, etc. The control box should have a bottom
gland plate for installing wire cord or conduit. To decide the size of control box, please refer to the
following Figure 4.
Complete set

Application
Basic Pumps,Controller Boxes,Solar Panels System Connection Method
Factory

FAQ
1.Is the price includes the solar panels?
No. If solar panel needed, Pls kindly let us know, we will quote accordingly (But we suggest purchasing PV panles locally to save high courier cost, further more, big size solar panels is very fragile during delivery via express)
2.How to choose the model?
Pls let me know your flow rate,Head,Power,Size,etc.We'll choose suitable one for you.
3.Can I buy just the pump without the controller?
No,our pump can only work with our controller.
4.How about the shipping?
All our products are free shipping,we'll choose suitable express for you.
5.How is the packaging?
Normally,we use export carton box.
6.What about the warranty?
Our 4SSC series time of warranty is 3 years.

7.If you've any other questions,welcome to contact us or leave us message.

Thank you for your visiting! Have a nice day.

View full details